Minimum Maximum
Filament voltage (Note1) 2.85 3.75 V
Cathode preheating time 0 - s
Peak anode voltage - 4.5 kV
Average anode current - 350 mAdc
Peak anode current - 1.2 A
Anode input power - 1.4 kW
Load VSWR (Note 2) - 4
Anode temperature (Note 3) - 300
Anode seal temperature (Note 4) - 320
Case temperature (Note 5) - 100
Storage temperature -30 60
東芝ホクト電子株式会社
製品一覧技術情報製品ガイド
お問い合わせ
会社案内 環境活動 品質方針 製品情報 アクセス 新着情報 English サイトマップ HOME
利用規約 個人情報保護方針 関係会社
  copyright
Power supply *1
Frequency 2460 MHz
Filament voltage 3.3 V
Peak anode voltage (Note 6) 4.10 kV
Average anode current 300 mAdc
Output power (matched load, Note 6) 900 W
Output power (typical oven by IEC 705) 850 W
Cooling air flow 1000 L/min
Pressure drop Approx. 95 Pa

The maximum ratings in this table which are interrelated should not be exceeded either individually or in combination under any worst case. Even if the maximum ratings are not exceeded, reduced life can occur as the operating conditions approach to the maximum ratings.

ABSOLUTE MAXIMUM RATING

TYPICAL OPERATION

RIEKE DIAGRUM
Operating condition Anode supply: Single phase full wave rectified without filter
Filament voltage : 3.3 V
Average anode current : 300 mA (constant)
Peak anode voltage (matched load) : 4.1 kV
Oscillating frequency (matched load) : 2460 MHz

製品一覧へ戻る

*1: Single phase full wave rectified without filter

東芝トップページ
2m301 Series image
2m301 Series refe