| Minimum | Maximum | ||
| Filament voltage (Note1) | 2.85 | 3.75 | V |
| Cathode preheating time | 0 | - | s |
| Peak anode voltage | - | 4.5 | kV |
| Average anode current | - | 350 | mAdc |
| Peak anode current | - | 1.2 | A |
| Anode input power | - | 1.4 | kW |
| Load VSWR (Note 2) | - | 4 | |
| Anode temperature (Note 3) | - | 300 | ℃ |
| Anode seal temperature (Note 4) | - | 320 | ℃ |
| Case temperature (Note 5) | - | 100 | ℃ |
| Storage temperature | -30 | 60 | ℃ |
| Power supply | *1 | |
| Frequency | 2460 | MHz |
| Filament voltage | 3.3 | V |
| Peak anode voltage (Note 6) | 4.00 | kV |
| Average anode current | 300 | mAdc |
| Output power (matched load, Note 6) | 860 | W |
| Output power (typical oven by IEC 705) | 730 | W |
| Cooling air flow | 1000 | L/min |
| Pressure drop | Approx. 95 | Pa |
The maximum ratings in this table which are interrelated should not be exceeded either individually or in combination under any worst case. Even if the maximum ratings are not exceeded, reduced life can occur as the operating conditions approach to the maximum ratings.
ABSOLUTE MAXIMUM RATING
TYPICAL OPERATION

RIEKE DIAGRUM
Operating condition Anode supply: Single phase full wave rectified without
filter
Filament voltage : 3.3 V
Average anode current : 300 mA (constant)
Peak anode voltage (matched load) : 4 kV
Oscillating frequency (matched load) : 2460 MHz
*1: Single phase full wave rectified without filter